France

Touraine Vallée de l'Indre Intermunicipality Office

France – Sorigny

Temperate Existing Building

Organisation : Communauté de Communes Touraine Vallée de l'Indre

18.0 %
annual energy
savings achieved
Level : Silver

Energy performance

18.0 %
Energy savings
27.9 kWh/m²/year
Absolute performance
0.4 kgCO₂/m²/year
Carbon intensity

Operational Context

The Hôtel Communautaire is a 1,605 m² public administration building in Sorigny, southwest of Tours in central France, serving as the headquarters of the Communauté de Communes Touraine Vallée de l'Indre — a federation of municipalities in the Indre Valley. The building houses approximately 65 staff members across the federation's administrative services.

 


Through participation in the 2023 CUBE competition, the Hôtel Communautaire achieved 22% energy savings, placing first in the Animation category and and 106th overall. This reduction was driven by a combination of light technical adjustments, including motion detectors in corridors with automated lighting controls, manual temperature controls in each office, and CO₂ sensors in shared offices to monitor air quality. There was also a focus on the use aspect: a volunteer green team with representatives from each service led an active engagement campaign through shared meals, climate workshops, eco-behavior quizzes, seasonal events, and regular CUBE updates posted throughout the building.

Key measures implemented

The main actions implemented to reduce the energy consumption of this building.

Technical Optimization

  • Manual temperature control in each office.
  • Installation of motion detectors in all corridors with automated lighting management.
  • Installation of educational CO₂ sensors in shared offices (indoor air quality monitoring).
  • Optimization of technical equipment usage, particularly video projectors.

Use Sufficiency

  • Creation of a green team on a voluntary basis (with one representative per department). 
  • Communication of CUBE energy reduction competition updates in common areas.
  • Organization of lunch meetings during the competition to present results and share best practices
  • Awareness activities such as climate workshop, eco-gesture quiz, and workshops on building energy renovation.
  • Organization of key events throughout the year such as ugly Christmas sweater day and a responsible summer barbeque. 

Technical context

Floor area 1,993 m²
Number of floors 2
Activity type Public Buildings & Civic Infrastructures
Year built 2015

Consumption data

Measurement periods

Reference period
Jan 2022 - Dec 2022
Monitoring period
Jan 2023 - Dec 2023

Annual Energy Impact